Introduction
If your physical sensor loses connectivity, you'll receive an email that reports the lost connection and provides its last known local IP address.
The following procedures, which appear in both the email and this article, should help you regain connectivity. The cause of the outage could be due to a network or power outage, a networking change, or a faulty sensor.
Please investigate the issue by checking your sensor for the following:
Troubleshooting Procedures:
Verify that the sensor is getting an IP address on your network
To verify that it's getting a local IP address, please check the following:
- Ping the sensor from your network.
- Ensure the sensor is receiving a local IP from your switch.
- If reachable by network, verify the connectivity using a self-check method such as:
- Connect to the sensor using SSH and open the Management Console or browse to the Field Effect Portal's Status Page and verify the sensor's connectivity status.
Verify that your firewall allows the sensor to establish outbound connections
If you can ping the sensor's IP address locally, the sensor is online - but it is unable to communicate back with Field Effect MDR.
If so, ensure that your firewall rules allow our relay connection as an outbound connection.
Use the Status Page to find your sensor's relay server hostname, which you need to allow as an outbound connection.
Verify the sensor's physical connections
Refer to your sensor's Configuration Guide and check the following for errors or faulty connections:
- Check network cables connecting the sensor.
- Check for power, and/or try a different power source.
- Ensure that the USB YubiKey (encryption module) is fully seated the port.
- Also try another USB port on the device if required.
- If you have been with Field Effect prior to 2026, your physical sensor shipped with a unique YubiKey, which is a security feature that works as a physical form of multi-factor authentication. Your device will not power on unless the YubiKey is plugged into a USB port. If Field Effect shipped your network sensor after June 2026, it doesn't require a YubiKey.
- Reboot the sensor.
- If the sensor does not come back online after a reboot, please connect a keyboard and monitor to the sensor.
- Check for a login prompt and login locally to the Management Console or browse to the Field Effect Portal's Status page.
Was this article helpful?